Vertical Check ValveDİK ÇEKVALF
TS EN 1074-3| Code | Size / spec | Box | |
|---|---|---|---|
| CKVD 70001012 | 1/2'' | 100 PCS | |
| CKVD 70001034 | 3/4" | 80 PCS | |
| CKVD 70001001 | 1'' | 50 PCS | |
| CKVD 70010114 | 1 1/4'' | 30 PCS | |
| CKVD 70010112 | 1 1/2'' | 30 PCS | |
| CKVD 70001002 | 2'' | 25 PCS |

Vertical (spring) and swing check valves plus Y-strainers: 1/2"–2" brass bodies, TS EN 1074-3. Protect pump, booster and mains lines against backflow.
| Code | Size / spec | Box | |
|---|---|---|---|
| CKVD 70001012 | 1/2'' | 100 PCS | |
| CKVD 70001034 | 3/4" | 80 PCS | |
| CKVD 70001001 | 1'' | 50 PCS | |
| CKVD 70010114 | 1 1/4'' | 30 PCS | |
| CKVD 70010112 | 1 1/2'' | 30 PCS | |
| CKVD 70001002 | 2'' | 25 PCS |
| Code | Size / spec | Box | |
|---|---|---|---|
| CKVC 70001012 | 1/2'' | 150 PCS | |
| CKVC 70001034 | 3/4" | 100 PCS | |
| CKVC 70001001 | 1'' | 50 PCS | |
| CKVC 70010114 | 1 1/4'' | 30 PCS | |
| CKVC 70010112 | 1 1/2'' | 30 PCS | |
| CKVC 70001002 | 2'' | 25 PCS |
| Code | Size / spec | Box | |
|---|---|---|---|
| PSLT 70001012 | 1/2'' | 150 PCS | |
| PSLT 70001034 | 3/4" | 50 PCS | |
| PSLT 70001001 | 1'' | 20 PCS | |
| PSLT 70010114 | 1 1/4'' | 12 PCS | |
| PSLT 70010112 | 1 1/2'' | 8 PCS | |
| PSLT 70001002 | 2'' | 5 PCS |
No matching product. Send us the code on WhatsApp and we will find it.
A check valve lets water flow in one direction only and closes automatically against backflow. It protects pumps, booster sets, boilers and mains connections. Bucak Metal supplies brass spring and swing check valves and Y-strainers from 1/2" to 2", listed under TS EN 1074-3.



A check valve, also called a non-return valve, has no handle. It is opened by the pressure of the flow itself and closes when the flow stops or reverses. This keeps pump lines primed, holds pressure in booster and tank systems, prevents contaminated water from returning to the mains and reduces water hammer.
A spring presses a disc onto its seat, so the valve closes quickly the moment flow stops. It works in horizontal and vertical lines and is the preferred choice at pump outlets, booster inlets and boiler cold-water inlets where water hammer matters. Code CKVD, six sizes from 1/2" to 2".
A hinged clapper swings open with the flow. The flow path is more open, so pressure loss is lower, which suits high-flow main lines and horizontal installations. In vertical lines it should only be used with upward flow. Code CKVC, 1/2"–2"; box quantity 150 for 1/2" and 25 for 2".
A Y-strainer holds sand, rust, scale and installation debris in a stainless screen. A single particle on a check valve seat can stop it from sealing, so installing a strainer upstream extends the life of check valves, ball valves and meters. Code PSLT, 1/2"–2".
| Feature | Spring check valve | Swing check valve |
|---|---|---|
| Closing element | Spring-loaded disc | Hinged clapper |
| Closing speed | Fast | Moderate |
| Pressure loss | Medium | Low |
| Orientation | Horizontal and vertical | Horizontal; vertical with upward flow only |
| Typical use | Pump outlets, boosters, boilers | Main lines, tank outlets, high flow |

Add codes and quantities from the tables below to your order list and send it on WhatsApp (+90 532 697 60 70). Combine with ball valves and brass fittings in the same order.
It allows flow in one direction only and closes automatically against backflow, protecting pumps, boosters, boilers and mains connections.
A spring check valve closes fast and works in any orientation; a swing check valve has lower pressure loss and suits horizontal, high-flow lines.
Spring and swing check valves and Y-strainers are available from 1/2" to 2".