Manifolds with integrated or mini valves (TSE K 534, 1" body, 2–12 outlets), butterfly-handle union valves and manifold valves with thermocouple — one source for underfloor heating and line distribution.
Manifold with Integrated Valves – ZebraKENDİNDEN VANALI KOLLEKTÖR - ZEBRA
TSE K 534
Code
Size / spec
Box
KLKV 90001002-Z
1" 2 - ağız
60 PCS
KLKV 90001003-Z
1" 3 - ağız
44 PCS
KLKV 90001004-Z
1" 4 - ağız
32 PCS
KLKV 90001005-Z
1" 5 - ağız
26 PCS
KLKV 90001006-Z
1" 6 - ağız
22 PCS
KLKV 90001007-Z
1" 7 - ağız
20 PCS
KLKV 90001008-Z
1" 8 - ağız
16 PCS
KLKV 90001009-Z
1" 9 - ağız
14 PCS
KLKV 90001010-Z
1" 10 - ağız
12 PCS
KLKV 90001011-Z
1" 11 - ağız
12 PCS
KLKV 90001012-Z
1" 12 - ağız
12 PCS
Manifold with Integrated ValvesKENDİNDEN VANALI KOLLEKTÖR
TSE K 534
Code
Size / spec
Box
KLKV 90001002
1" 2 - ağız
60 PCS
KLKV 90001003
1" 3 - ağız
44 PCS
KLKV 90001004
1" 4 - ağız
32 PCS
KLKV 90001005
1" 5 - ağız
26 PCS
KLKV 90001006
1" 6 - ağız
22 PCS
KLKV 90001007
1" 7 - ağız
20 PCS
KLKV 90001008
1" 8 - ağız
16 PCS
KLKV 90001009
1" 9 - ağız
14 PCS
KLKV 90001010
1" 10 - ağız
12 PCS
KLKV 90001011
1" 11 - ağız
12 PCS
KLKV 90001012
1" 12 - ağız
12 PCS
Manifold with Mini Valves – ZebraMİNİ VANALI KOLLEKTÖR - ZEBRA
TSE K 534
Code
Size / spec
Box
KLMV 90001002-Z
1" 2 - ağız
60 PCS
KLMV 90001003-Z
1" 3 - ağız
44 PCS
KLMV 90001004-Z
1" 4 - ağız
32 PCS
KLMV 90001005-Z
1" 5 - ağız
28 PCS
KLMV 90001006-Z
1" 6 - ağız
22 PCS
KLMV 90001007-Z
1" 7 - ağız
20 PCS
KLMV 90001008-Z
1" 8 - ağız
16 PCS
KLMV 90001009-Z
1" 9 - ağız
14 PCS
KLMV 90001010-Z
1" 10 - ağız
14 PCS
KLMV 90001011-Z
1" 11 - ağız
12 PCS
KLMV 90001012-Z
1" 12 - ağız
12 PCS
Manifold with Mini ValvesMİNİ VANALI KOLLEKTÖR
TSE K 534
Code
Size / spec
Box
KLMV 90001002
1" 2 - ağız
60 PCS
KLMV 90001003
1" 3 - ağız
44 PCS
KLMV 90001004
1" 4 - ağız
32 PCS
KLMV 90001005
1" 5 - ağız
28 PCS
KLMV 90001006
1" 6 - ağız
22 PCS
KLMV 90001007
1" 7 - ağız
20 PCS
KLMV 90001008
1" 8 - ağız
16 PCS
KLMV 90001009
1" 9 - ağız
14 PCS
KLMV 90001010
1" 10 - ağız
14 PCS
KLMV 90001011
1" 11 - ağız
12 PCS
KLMV 90001012
1" 12 - ağız
12 PCS
Butterfly Handle Union Valve PN10KELEBEK KOLLU RAKORLU VANA PN10
TS EN 13828
Code
Size / spec
Box
PN10 30001012
1/2"
120 PCS
PN10 30001034
3/4“
100 PCS
PN10 30001001
1“
60 PCS
PN10 30010114
1 1/4“
40 PCS
PN10 30010112
1 1/2“
30 PCS
PN10 30001002
2“
15 PCS
Butterfly Handle Union Valve PN25KELEBEK KOLLU RAKORLU VANA PN25
TS EN 13547
Code
Size / spec
Box
PN25 30002512
1/2"
120 PCS
PN25 30002534
3/4“
100 PCS
PN25 30002501
1“
60 PCS
PN25 30025114
1 1/4“
40 PCS
PN25 30025112
1 1/2“
30 PCS
PN25 30002502
2“
15 PCS
Manifold Valve with Thermocouple, Butterfly Handle PN10TERMOKUPLU KELEBEK KOLLU KOLLEKTÖR VANA PN10
TS EN 13828
Code
Size / spec
Box
PN10 30001112
1/2"
120 PCS
PN10 30001134
3/4“
100 PCS
PN10 30001101
1“
60 PCS
PN10 30111114
1 1/4“
40 PCS
PN10 30111112
1 1/2“
30 PCS
PN10 30001102
2“
15 PCS
Manifold Valve with Thermocouple, Butterfly Handle PN25TERMOKUPLU KELEBEK KOLLU KOLLEKTÖR VANA PN25
TS EN 13547
Code
Size / spec
Box
PN25 30002612
1/2"
120 PCS
PN25 30002634
3/4“
100 PCS
PN25 30002601
1“
60 PCS
PN25 30261114
1 1/4“
40 PCS
PN25 30261112
1 1/2“
30 PCS
PN25 30002602
2“
15 PCS
No matching product. Send us the code on WhatsApp and we will find it.
A manifold is the distribution centre of an underfloor heating system. Each room loop starts and ends at the manifold, where it can be opened, closed and balanced independently. Bucak Metal supplies brass manifolds with a 1" body and 2 to 12 outlets.
Valved manifoldMini-valved manifoldManifold assembly line
What is a manifold?
In an underfloor heating system, the flow manifold distributes hot water from the boiler to each loop and the return manifold collects it back. Valves on each outlet allow one room to be shut off or balanced without affecting the others. Manifolds are also used in radiator systems with home-run piping and in hot and cold water distribution.
Manifold types
Valved manifold (KLKV): integrated valve on every outlet; 1" body, 2–12 outlets, TSE K 534.
Mini-valved manifold (KLMV): compact valves that save space in narrow manifold cabinets.
Zebra series: the same dimensions with a different surface finish for visible cabinets.
Manifold ball valves: butterfly-handle union valves in PN10 and PN25, plus thermometer versions, 1/2"–2".
Pipes are laid in separate loops per room and joined at the manifold.
How many outlets do you need?
The number of outlets equals the number of loops. With 16 mm pipe, a loop is usually kept under 80–100 m, which covers roughly 10–15 m² depending on pipe spacing.
Home
Approx. area
Typical outlets
1 bedroom
50–65 m²
3–4
2 bedrooms
80–100 m²
5–6
3 bedrooms
110–140 m²
7–9
4+ bedrooms
160 m² +
10–12 or two manifolds
The final number comes from the heat-loss calculation and the floor plan.
Installation tips
Place the manifold centrally so loop lengths stay balanced.
Bleed each loop separately when filling the system.
Label every outlet with the room it serves.
Pressure-test the system before the screed is poured.
Box quantities are 60 for 2-outlet and 12 for 12-outlet manifolds. Add codes to your order list and send it on WhatsApp (+90 532 697 60 70).
Frequently asked questions
What does an underfloor heating manifold do?
It distributes hot water to each heating loop and collects the return, allowing each room to be opened, closed and balanced separately.
How many outlets does a manifold need?
One outlet per loop. A two-bedroom home typically needs 5–6 outlets and a three-bedroom home 7–9.
Which manifold sizes are available?
Valved and mini-valved manifolds with a 1" body and 2 to 12 outlets.
How should an underfloor heating manifold be selected?
Selection depends on circuit count, connection sizes and the control components required by the project. Features such as flow adjustment or automation compatibility must be checked for the exact model. State the required configuration in the quotation request.
Send the code and quantity — get your quote on WhatsApp.