PE-RT underfloor heating pipes

16x2 PE-RT pipes with and without oxygen barrier — flexible, corrosion-resistant and long-lasting for underfloor heating, drinking water and modern plumbing.

PE-RT Pipe without Oxygen BarrierPE-RT OKSİJEN BARİYERSİZ BORU

CodeSize / specBox
MMPR-ŞEFF-16000216X2 -Optional
MMPR-ŞEFK-16000216X2 KIRMIZIOptional
MMPR-ŞEFM-16000216X2 MAVİOptional

PE-RT Pipe with Oxygen BarrierPE-RT OKSİJEN BARİYERLİ BORU

CodeSize / specBox
MMPR-KIRM-16000216X2 -Optional
MMPR-KIRK-16000216X2 KIRMIZIOptional
MMPR-KIMM-16000216X2 MAVİOptional

In underfloor heating the pipe is buried in the screed for decades, so it is the hardest part to replace. Bucak Metal supplies 16x2 mm PE-RT pipes with and without an oxygen barrier.

PE-RT oxygen barrier – red
PE-RT oxygen barrier – red
PE-RT – blue
PE-RT – blue
PE-RT coil
PE-RT coil

Why PE-RT?

  • Flexible: supplied in coils, easy to lay in tight loops without cracking.
  • Temperature resistant: designed for continuous operation at underfloor heating temperatures.
  • Corrosion-free: no rust, no scale.
  • No joints under the screed: each loop runs as one piece from manifold to manifold.

Oxygen barrier or not?

With oxygen barrierWithout barrier
Recommended forClosed heating circuitsOpen circuits, sanitary use
Protects boiler, pump, manifoldYesLimited
ColoursRed, blue, standardClear, red, blue
Loops are laid at even spacing and connected to the manifold.
Loops are laid at even spacing and connected to the manifold.

How much pipe per m²?

Pipe spacingApprox. pipe per m²
10 cm~10 m
15 cm~6.7 m
20 cm~5 m

Add connection runs to the manifold. A loop is usually kept under 80–100 m; total length divided by loop length gives the number of manifold outlets.

Installation tips

  • Uncoil the pipe by rolling, never pull it into a kink.
  • Leave no joints under the screed.
  • Pressure-test before pouring and keep the system under pressure during pouring.

Request a quotation

Coil length is optional. Send your floor area or pipe length and loop count on WhatsApp (+90 532 697 60 70); we can quote pipes, manifolds and connectors together.

Underfloor Heating Pipes and Manifolds from Turkey

Bucak Metal's product groups include PE-RT underfloor heating pipes and manifolds. Contractors and purchasing teams can request a quotation by providing the pipe specification, total length and required manifold configuration. Treating the pipe, manifold and connection components as one purchasing package helps make the project requirements clear.

A request for 16 mm underfloor heating pipe should identify more than the external diameter. Wall thickness, pipe construction, any oxygen barrier requirement and the manufacturer's operating conditions should be reviewed against the system design. Pipe spacing and circuit lengths are design decisions that depend on heat-loss and hydraulic calculations, not on diameter alone.

The manifold distributes flow to the heating circuits. The number of circuits, connection sizes and required control components should therefore be specified before products are compared. Flow adjustment, actuators or automation compatibility should be confirmed for the selected model rather than treated as standard features of every manifold.

Send Bucak Metal your pipe lengths, dimensions, manifold circuit count and delivery destination to request pricing and availability. Include the project specification where available. International buyers can also identify documentation and delivery requirements in the enquiry, allowing the proposed supply to be assessed against the needs of the project.

Share your underfloor heating bill of materials to request a quotation.

Frequently asked questions

What size pipe is used for underfloor heating?

16 mm outside diameter with 2 mm wall thickness (16x2) is the standard residential size.

Is an oxygen barrier necessary?

It is recommended for closed heating circuits because it prevents oxygen from entering the water and corroding metal components.

How many metres of pipe per m²?

About 10 m at 10 cm spacing, 6.7 m at 15 cm and 5 m at 20 cm, plus connection runs.

Is 16 mm underfloor heating pipe suitable for every project?

No. Diameter alone does not establish suitability. Heat loss, circuit length, flow, pipe construction and operating conditions must be considered together. Include the pipe specification defined by the project in your enquiry to Bucak Metal.