16x2 PE-RT pipes with and without oxygen barrier — flexible, corrosion-resistant and long-lasting for underfloor heating, drinking water and modern plumbing.
| Code | Size / spec | Box | |
|---|---|---|---|
| MMPR-ŞEFF-160002 | 16X2 - | Optional | |
| MMPR-ŞEFK-160002 | 16X2 KIRMIZI | Optional | |
| MMPR-ŞEFM-160002 | 16X2 MAVİ | Optional |
| Code | Size / spec | Box | |
|---|---|---|---|
| MMPR-KIRM-160002 | 16X2 - | Optional | |
| MMPR-KIRK-160002 | 16X2 KIRMIZI | Optional | |
| MMPR-KIMM-160002 | 16X2 MAVİ | Optional |
No matching product. Send us the code on WhatsApp and we will find it.
In underfloor heating the pipe is buried in the screed for decades, so it is the hardest part to replace. Bucak Metal supplies 16x2 mm PE-RT pipes with and without an oxygen barrier.



| With oxygen barrier | Without barrier | |
|---|---|---|
| Recommended for | Closed heating circuits | Open circuits, sanitary use |
| Protects boiler, pump, manifold | Yes | Limited |
| Colours | Red, blue, standard | Clear, red, blue |

| Pipe spacing | Approx. pipe per m² |
|---|---|
| 10 cm | ~10 m |
| 15 cm | ~6.7 m |
| 20 cm | ~5 m |
Add connection runs to the manifold. A loop is usually kept under 80–100 m; total length divided by loop length gives the number of manifold outlets.
Coil length is optional. Send your floor area or pipe length and loop count on WhatsApp (+90 532 697 60 70); we can quote pipes, manifolds and connectors together.
Bucak Metal's product groups include PE-RT underfloor heating pipes and manifolds. Contractors and purchasing teams can request a quotation by providing the pipe specification, total length and required manifold configuration. Treating the pipe, manifold and connection components as one purchasing package helps make the project requirements clear.
A request for 16 mm underfloor heating pipe should identify more than the external diameter. Wall thickness, pipe construction, any oxygen barrier requirement and the manufacturer's operating conditions should be reviewed against the system design. Pipe spacing and circuit lengths are design decisions that depend on heat-loss and hydraulic calculations, not on diameter alone.
The manifold distributes flow to the heating circuits. The number of circuits, connection sizes and required control components should therefore be specified before products are compared. Flow adjustment, actuators or automation compatibility should be confirmed for the selected model rather than treated as standard features of every manifold.
Send Bucak Metal your pipe lengths, dimensions, manifold circuit count and delivery destination to request pricing and availability. Include the project specification where available. International buyers can also identify documentation and delivery requirements in the enquiry, allowing the proposed supply to be assessed against the needs of the project.
Share your underfloor heating bill of materials to request a quotation.
16 mm outside diameter with 2 mm wall thickness (16x2) is the standard residential size.
It is recommended for closed heating circuits because it prevents oxygen from entering the water and corroding metal components.
About 10 m at 10 cm spacing, 6.7 m at 15 cm and 5 m at 20 cm, plus connection runs.
No. Diameter alone does not establish suitability. Heat loss, circuit length, flow, pipe construction and operating conditions must be considered together. Include the pipe specification defined by the project in your enquiry to Bucak Metal.